For Servers and Other Networking Equipment
Online UPS 10-20 kVA Three Phase/Single Phase
• Online Double Conversion
• Non Transfer Time of Output
• PFC Technology
• Full Digital Control (DSP)
• Output Power Factor: 0.8
• Input Current Harmonic: 5%
• Economic Operation Mode (ECO)
• Optimization Battery Group: 16/18/20 Pieces (Optional)
• Wide Input Voltage Range: 304~478VAC
• Input Over/under-Voltage Protection
• Automatic Bypass
• Cold Start (DC)
• Fault Isolation
• RS232 Com. Port With Monitoring Software
• Optional: SNMP Card/Centralized
• Monitoring Card/ Parallel Port Module
Spower Shark 3 Phase in 1 Phase Our UPS -Technical Features |
| | Model | | | Capacity | 10kVA / 8kW | 15kVA / 12kW | 20kVA / 16kW | | Input | | | Phase | 3 Phase 4 Wires and Ground | | Rated Voltage | 380/400VAC | | Voltage Range | 304~478VAC | | Frequency Range | 40~70Hz | | Power Factor | ≤0.99 | | Bypass Voltage Range | Max. Voltage: +15% (Optional +5%, +10%, +25% ) Min. Voltage: -45% (Optional -20%, -30%) Frequency Protection Range: 10% | | ECO Range | Same as Bypass | | Current Harmonic | ≤5% (100% Non-linear Load) | | Output | | | Phase | Single Phase & Ground | | Rated Voltage | 220/230VAC | | Power Factor | 0.8 | | Voltage Precision | ±2% | | Output Frequency | Utility Mode | ±1%, ±2%, ±4%, ±5%, ±10% Of The Rated Frequency (Optional) | | Battery Mode | (50 ±0.2)Hz | | Crest Factor | 3:1 | | Transfer Time | Utility to Battery : 0ms Utility to Bypass : 0ms (Following) | | Overload Capability | Load 110% 60min, 125% Last 10min, 150% Last 1min, 150% Shut Down UPS Immediately | | THD | ≤2% | | Transfer Time | 0ms | | Efficiency | Efficiency ECO Mode 98%; Normal Mode 90% | | Battery | | | Voltage | Voltage ±96V±108V±120V DC; Battery Quantity (Optional) | | Backup Time | Full Load 2min (10kVA Standard Unit), Long Time Unit Depends on The Capacity of External Catteries | | Charge Current (A) | 1A (10KVA Standard unit); Long Time Unit Maximum Current 6A | | Operating Environment | | | Temperature | 0~40°C | | Humidity | 0%~95% (Non-Condensing) | | Altitude | <1500m | | Storage Temperature | -25~55°C | | Other | | | Communication Interface | RS232, Dry Contact, Centralized Monitoring Card Optional (RS485,SNMP, Parallel Card) | | Dimension (W×D×H) (mm) | 250×590×655 | 250×590×655 | 250×590×655 | | Weight (kg) | 80(Standard Unit) 40(Long Time Unit) | 45 | 45 | | Industry Standard | CE,EN/IEC 62040-2,EN/IEC 62040-1-1 | | Spower Energy reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Spower Energy products previously or subsequently sold. Spower Energy does not guarantee the items of the accuracy and completeness
|
|